M302 p1. 8Hz when using P4. M302 p1

 
8Hz when using P4M302 p1 28" ; configure active-high endstop for low end on Y via pin null; Z-Probe M558 P0 H5 F120 T6000 ; disable Z probe but set dive height, probe speed and travel speed M557 X15:215 Y15:195 S20 ; define mesh grid M308 S0 P"P0

M569 P0 S1 ; Reverse the X motor M563 P0 D0 H1 ; Define tool 1 G10 P0 S0 R0 ; Set tool 1 operating and standby temperatures M563 P1 D1 H2 ; Define tool 2 (un-comment this for dual nozzle machines) G10 P1 X19 S0 R0 ; Set tool 2 operating and standby temperatures (un-comment this for dual nozzle machines) M92 E447:447 ; Set. There is no minimum steps/mm set in the firmware. M84 E ; turn off E motorG29 P1 ; invalidate mbl & probe print areaG29 P1 X0 Y0 W50 H20 C ; probe near purge placeG29 P3. @deckingman Replacing the P1 with P0 in the config file was the trick! Now the retract option is available immediately when I activate the hot end heater, and when it reaches 160c, the extrude option is now available. This topic has been deleted. 5beta2 regarding the 'M302 P1' cold extrusion command. 2 the M302 P1 command doesn't help to allow the cold extrusion anymore. Sending T0 initiates the heater and then faults out. I used to use "Pronterface" for that. 00°C/sec. . Once satisfied the extruder drive is working, re-enable cold extrusion prevention using the following command: M302 P0 Reset the Active temperature for Heater 1 back to 190C. Last edit at 01/11/2023 01:58AM by Dust. Command "M302 P1" works properly. M302 P1 Now advance the filament using the jog buttons on the Manual Control tab, until it reaches the top of the heatsink. I use FreeBSD 13. I'm at a dead end where I can't seem to get the E0 Stepper motor to. 4. 3 or later ;M17 A B G92 A0 B0 G1 A0 B0 F20000. Always getting "ERROR: Preheat the Nozzle!". Large delta printer [miscsolutions. Dear all i have 4 heaters, when i try to heat all of them at same time, it automatically goes to standby mode, what will be reason? when i individually heat them it works fine. Thermostatic control is turned on > 45C turn on ;M106 P1 S255 H-1 M302 P1 ; Allow cold extrusion (for testing) T0 ; Set tool 0 (default extruder) G21 ; Work in millimetres G90 ; Send absolute coordinates. It may have allowed the extruder to run on the 6HC but I'm thinking the DWC may have still been blocking the sending of any extrude or retraction presses while it looked only at the temperature before enabling the sowtware buttons. If that's not the case, we need to change the direction of rotation. In order to report the current status, run. 8 S1. 0 S1 ; Enable network and acquire dynamic address via DHCP M586 P0 S1 ; Enable HTTP M586 P1 S0 ; Disable FTP M586 P2 S0 ; Disable. $egingroup$ That fix, sending M302 P1 (the P1 is important) and then M500 can be done in any program that can communicate directly with the printer. Extrude a small amount to ensure that your extruder motor is on and holding. I'm attempting to drive I was successful in driving a Maxon DC motor with encoder (pulled from a Stratasys Dimension 1200es BST) with a Duet 2 Wifi via a Geckodrive G320x Digital. GameStop Moderna Pfizer Johnson & Johnson AstraZeneca Walgreens Best Buy Novavax SpaceX Tesla. Both Agisoft and Pix4d do some weird color smoothing that makes the meshes much less crisp looking. 1 Reply Last reply Reply Quote 0. Send T0 before you try to extrude. Sending M302 P1 shows green as though it accepts the command, but the extrude & retract buttons are still grayed out. Failure to extrude in RepRapFirmware is usually caused by either cold extrusion prevention (but you have sent M302 P1 to disable that), or not having the tool selected. g. This topic has been deleted. 0. 0 S1 ; Enable network and acquire dynamic address via DHCP M586 P0 S1 ; Enable HTTPM302 P1;M563 P0 D3:4 ; Define tool 0 (no heaters assigned);M567 P0 E1:1;M584 E3:4;M302 P1 ;COLD EXTRUSION ON; Network M550 PXTP1 ; Set machine name M540 PBE:EF:DE:AD:FE:ED ; Set MAC address M552 P0. 3 ; Filter. La commande G-code M302 P1 permet l'extrusion a froid. Viko. M302 P1 ; allow cold extrusion. Features solid metallic core with. I probed the STEP output with an oscilloscope and the pulses are there and the pulse length is fine. 0C. Hi all, It turned out to be the end-stops micro switches causing the board to lose connection. Description The M2 Carbine is. Retract 150 mm of. 3 E40 ; set drive mapping. 7. @2:0 SENT: M302 RECEIVED: ok 0 RECEIVED: Cold extrusion allowed RECEIVED: wait Zum Test verwende ich immer Folgendes: G91 G1 E500 F3000 1-mal bearbeitet. This topic has been deleted. M302 P1 ; Allow Cold extrudes M98 Pmachine_maxtemp. Still no luck with Extrusion Control jogging buttons. dc42 administrators @dsela last edited by dc42 . e. Disable any mesh bed leveling procedures in. Extrude a little more filament: G1 E20 F200; Measure as accurately as you can using a rule between your marks. M302 P0 ; disable cold extrusion M291 P"Filament autoload complete!" S0 T3 ; display message . trigger3. @deckingman Replacing the P1 with P0 in the config file was the trick! Now the retract option is available immediately when I activate the hot end heater, and when it reaches 160c, the extrude option is now available. M569 P1. g . Failure to extrude in RepRapFirmware is usually caused by either cold extrusion prevention (but you have sent M302 P1 to disable that), or not having the tool selected. @patel said in how to change homing sequence: corexy printer setup how to change sequence homing x,y i am using M3D promega and i need to change sequence first y axis home after x axis manual working fine by hand trigger switch x limit and y limit See h. CryptoThis topic has been deleted. @agent0810 said in Homing advice: but then when i tried to home it sent the bed to the bottom Then we need to change the motor direction for Z like we did for the X and Y. 0. Failure to extrude in RepRapFirmware is usually caused by either cold extrusion prevention (but you have sent M302 P1 to disable that), or not having the tool selected. 43 M562 Reset Temperature Fault [Pnn] Reset temp fault on all heaters or on heater Pnn M562. Large delta printer [miscsolutions. Thermostatic control is turned off ; Fan for the hotend M950 F1 C"out6" L0:1000 Q50 ; create fan 1 on pin out6 and set its frequency M106 P1 S1 H1 T45 C"Hotend" ; set fan 1 value. . M302 P1 ; enable cold extrusion M201 E1000 ; reduce extruder acceleration M915 P3 S10 F0 R0 ; set stall detection threshold M913 E100 ; set extruder motor to reduced % current M83 ; relative extrusion G1 S1 E800 F3600 ; move fast 500mm of filament M913 E100 ; set extruder motor to full current M302 P0 ; disable cold extrusion G1 E50 F300. ; pre 3. 3 ; Filter. M302 P1 ; Allow Cold extrudes M98 Pmachine_maxtemp. droftarts administrators @flyscha last edited by . This topic has been deleted. G1 E20 moves E0 as expected T1 changes tools as expected G1 E30 move E1 as expected. The button movement range is about 0. 0. Tried M302 P1 four times. short Signal and +3. Hi, Bringing up my re-controlled Vivendo Troodon 400 with a 6HC and 3HC. Support and Discussion forum for Duet3D Hardware, Firmware, Software, plugins and wider 3d printing/CNC discussion. According to the docs, putting nothing or 0 means infinity. P1: Stroke: CT/CTA should also be considered; Appendicitis: MRI rarely indicated. This is the stuff I'm finishing for 2019, they are hairpins in two colors that I do with an advanced Pause script that allows me to Atomic plug the filament totally unmanned and waits for me until I go to change the color and click resume. gco M24 Start/resume SD print M25 Pause SD print M26 [S(Bytes(s)/Pnn] Set SD position. 0. Only users with topic management privileges can see it. Make anothe mark on the filament right where it leaves the fitting. @jfavre Are you sure you have a tool selected (with T0, you will need that as well as the M302 P1)? What response did you get to M302 (before and after you set M302 P1)? Have you tried heating the nozzle? 1 Reply Last reply Reply Quote 0. Sending M302 P1 shows green as though it accepts the command, but the extrude & retract buttons are still grayed out. So please send T0 and M302 P1 and then see if you can send G1 E1 F100 to make. I made my own slicer for the concrete printer, but for some reason the layer change is not detected, so my "Last Layer Time" is not updated. 3. microswitch) endstop. Direct drive: Remove your nozzle, hotend, or extruder. Now with Marilin 2. This topic has been deleted. To temporarily disable the MIN_TEMP, you need to run the G-code M302 P1 or M302 S0 - M302 on its own does nothing. retraction temperature 90. M302 P1 ;allow cold extrusion T0 G1 E1000 F3600 ;new step/mm = old*1000/Measured ;example 1024 measured with old steps = 310 -> new = 310*1000/1024 = 302. 4. Your config files updated for bugfix Configuration. the X motor. 2nd print: 10seconds permanent skipping at 10x30 at layer 18mm. I have almost everything working: Temp sensors All the axis drives including 4-Z steppers. So please send T0 and M302 P1 and then see if you can send G1 E1 F100 to make. @agent0810 said in Homing advice: the z is at 0 at the top, so it cant go lower right? shouldnt it home at 300 something? im having issues moveing the bed. I have been clicking the 'retract' and 'extrude' button multiple times to push the plunger down to the correct position and to retract the plunger from the bottom of the cylinder after the print. dmould. com], E3D tool changer, Robotdigg SCARA printer, Crane Quad and OrmerodDisclosure: I design Duet electronics and work on RepRapFirmware, []. UPC: 756122055144. droftarts administrators @flyscha last edited by . 7. G-Code commands¶@jfavre said in Extruder motor not working. Fix the actual problem, which is that Marlin has a safety feature to protect the extruder and hotend by preventing extrusion when the temperature is below a certain margin. Expected behavior: The Unload should ignore the temperature on the Hotend and do its thing. M302 P1 ; allow cold extrude M302 S0 R0 ; allow cold extrude;M563 P1 P3 S"filament" D1 H1 H3 F4 ; define tool 1;G10 P1 X0 Y0 Z0 ; set tool 1 axis offsets ;G10 P1 R0 S0 ; set initial tool 1. M302 P1 disables the cold extrude safety. Retract 150 mm of filament, then remove it from the filament drive. Thermostatic control is turned off. However, a steps/mm value of 5. the X motor. Connector for the extruder is plugged into second connection (i. This is by far the only way I am able to see that the steppers can actually work through the board. 8 is far too low for two reasons: 1. M302 P1 ; Allow cold extrusion Just enter the above code from your host software (pronterface or repitear) and you should be good to test the paste extruder. 3 or later ;M17 A B G92 A0 B0 G1 A0 B0 F20000. Hello there So the problem is as follows: when I manually send a G1 command like (G1 F200 E1) the printer extrudes nice and slow but 'retracts' to the starting position very fast. GameStop Moderna Pfizer Johnson & Johnson AstraZeneca Walgreens Best Buy Novavax SpaceX Tesla. 0. 9 Windows 10 I am using a macro in reprapFirmware to pause the print for a certain length of time after evey layer. I updated webcontrol and firmware several times without error, but no change. Why happening freezes while running this g-code? G28 ; Homing T0 ; Select tool T0 M83 ; Extruder to relative mode M302 P1 ; Allow cold extrudes G1 X20 F9000 G1 X80 E1 F9000 ;freeze G1 X120 F9000 G1 X80 E1 F9000 ;freeze G1 X20 F9. GameStop Moderna Pfizer Johnson & Johnson AstraZeneca Walgreens Best Buy Novavax SpaceX Tesla. J'y connais pas grand chose dans les imprimantes 3D, moi jusque là, ça fonctionnais donc je ne m’intéressai pas trop au reste, mais là, je suis bien obligé, et donc je ne sais pas faire la commande G-code que tu m'indique, ou faire ça dans Repetier-Host ?M302 P1 ; cold extrude. M302 P1 disables the cold extrude safety. And now even Col Extrusion M302 P1 is generating errors. M83 ; set extruder to relative mode echo "Start" G1 E60 F150 ; Extrude 60mm at 2. 13. In order to report the current status, run. Sending M302 P1 shows green as though it accepts the command, but the extrude & retract buttons are still grayed out. Sending M302 P1 shows green as though it accepts the command, but the extrude & retract buttons are still grayed out. 00" standard bore "competition" gasket for cast iron or aluminum cylinder heads on 302 and 351W production blocks. I cannot get the extruder controls to show up in the web interface - it is greyed out. G10 P1 X0 Y0 Z0 ; Set tool 1 axis offsets G10 P1 R0 S0 ; Set initial tool 1 active and standby temperatures to 0C M302 S120 R110 ; Allow extrusion starting from 120°C and retractions already from 110°C Failure to extrude in RepRapFirmware is usually caused by either cold extrusion prevention (but you have sent M302 P1 to disable that), or not having the tool selected. 06. ) You can feed filament at 800mm/m (web interface max speed is 240mm/m), at 100mm at a time, until the filament is near the nozzle. Reply Quote. However,. M302 P0 disallows cold extrusion. 0. 8 is far too low for two reasons: 1. Hello. 8. if I'd have sent the extrude G code it probably would've extruded. M302: Allow cold extrudes add cancelling of the command; M561: Set Identity Transform - reset the transformation from calibration; Non specific G-codes Movement. Direct drive: Remove your nozzle, hotend, or extruder. 1 Reply Last reply Reply Quote 0. I can't help you with fans on RADDS, but "Attempting to extrude with no tool selected" means just that. Don't expect G0 or G1 to make it move, when not homed. Sending M302 P1 shows green as though it accepts the command, but the extrude & retract buttons are still grayed out. 5mm/sec echo "Done" M82 ; set extruder to abs mode 1 Reply Last reply Reply Quote 0There is one extra complication in moving the extruder. 4. 1. After creating these and making all the connections we can move onto updating the firmware. After replacing PCB managed to get everything up and running. 00°C/sec. g ; Unload to above y-splitter. R"Filament out" S2 ; Step 3 > After checking you click okay and it starts reversing filament M302 P1 ; Allow cold extrusion G1 E-520 F3000 ; Unwind the filament 400mm ; Step 4 > Notify user and offer option to place new filament M291 P"Remove remaining filament, insert new filament and continue" R"Insert new filament" S2 G1 E480. 86272-ad-b. Don't forget to send M302 P0 later to restore normal safety. 0 S1 ; Enable network and acquire dynamic address via DHCP M586 P0 S1 ; Enable HTTP M586 P1 S0 ; Disable FTP M586 P2 S0 ; Disable. retraction temperature 90. The prototype was outsourced to Oshpark. The M2 Carbine rifle is a fully automatic version of the M1A1. 0 S1 ; Enable network and acquire dynamic address via DHCP M586 P0 S1 ; Enable HTTPThermostatic control is turned on. M302 P1 (This will revert the next time you reset or power off the Duet, or you can send ‘M302 P0’. Re: How can I move E steppers? January 11, 2023 02:36AMI used the safety scissors to cut off the fingers of the severed hand then tried to give her the fingers. CryptoM21 P1 M22 Release SD card M23 [filename. The Matrice 30 series integrates multiple high-performance sensors into a lightweight and portable body. @2:0 SENT: M302 RECEIVED: ok 0 RECEIVED: Cold extrusion allowed RECEIVED: wait Zum Test verwende ich immer Folgendes: G91 G1 E500 F3000 1-mal bearbeitet. 1 Reply Last reply Reply Quote 0. droftarts administrators @flyscha last edited by . @dc42 Having seen your post I also checked the frequency on a multimeter and indeed it shows 49. In order to report the current status, run. 36°C/sec measured -0. If calibrating cold: Bowden: Disconnect the bowden tube from your extruder. Large delta printer [ miscsolutions. M808. Last edit at 01/11/2023 01:58AM by Dust. HI again, what I'm doing wrong, the extruder buttons in DWC won't be gray, its grayed out. wordpress. Chances are you are getting a message saying either "Attempt to extrude with no tool selected" or "Tool n was not driven because its heaters were not hot enough". Business, Economics, and Finance. Then reduce the distance, and stop just before the filament disappears into the hot end. It has a different internal construction. 3V is removed from the E1STOP signal, in which case the log will display the command entered. 5 and 1. Extrusion Control in DWC unavailable, even after M302 P1. You could do it it by turning off the safety limit which prevents cold extrusion. For coding you should add M302 P0 to your ending gcode to re-enable the safety at the end of the file. Re: How can I move E steppers? January 11, 2023 02:36AMSo are you still getting phase errors, or is that resolved? @jfavre said in Extruder motor not working. x) G92 A-1 B-1 ; Make Zrot & Tilt active G1 A0 B0 ; 3. It will not move when the hotend is cold as a safety feature in the firmware. Sending M302 P1 shows green as though it accepts the command, but the extrude & retract buttons are still grayed out. : Heater 1 fault: temperature rising too slowly: expected 2. 22. But when i try to run it from DWC, I get the error: M302 ; report current cold extrusion state M302 P0 ; enable cold extrusion checking M302 P1 ; disable cold extrusion checking M302 S0 ; always allow extrusion (disable checking) M302 S170 ; only allow extrusion above 170 M302 S170 P1 ; set min extrude temp to 170 but leave disabled M302 P1 M584 E3:4;M563 P0 D3:4 ; Define tool 0 (no heaters assigned);M567 P0 E1:1;M584 E3:4;M302 P1 ;COLD EXTRUSION ON; Network M550 PXTP1 ; Set machine name M540 PBE:EF:DE:AD:FE:ED ; Set MAC address M552 P0. Here is a handy list of g-code commands [ reprap. -> no reaction at all - even after "M302 P1" What is working: Homing. You want to leave that in case the bed or anything else still has a heater, and it wouldn't fix your problem anyway. 0C, min. Duet Web Control makes it easy to upload, edit and create new macros. T0, you need to either heat up that tool, or enable cold extrusion by sending M302 P1. I have to turn the power off and on to reset it. M109 S235 T0 ; set hotend temperature and wait. P1 S1 S1 S1 Lc 4 DTR COM1 5 Signal Ground 6 DSR. So I attached a thermistor to the board just to "fool" the board into thinking there was an active heater but then I get temperature errors. Set the temperature (and enable) using. 1 Reply Last reply Reply Quote 0. Set the temperature (and enable) using. : Just need to find settings for Slice Engineering 300c thermistor, According to this document, you need to use the following in your M308 T100000 B4680 C6. Does the motor turn? If yes, then probably it’s not having enough power to push the filament through the nozzle. 5mm/sec echo "Done" M82 ; set extruder to abs modeBusiness, Economics, and Finance. droftarts administrators @flyscha last edited by . 1 Reply Last reply Reply Quote 0. Sending M302 P1 shows green as though it accepts the command, but the extrude & retract buttons are still grayed out. yello3d. extrusion temperature 160. Trying to figure out why I can't run my extruder. Send M302 P1 to allow cold extrusion. I use duet wifi version 1. M302 P1 ; allow cold extrusion. 100". M122 shows some weird. . . g. Anytime I extrude a certain length of filament, the extruder retracts the same length it seems. 455513e-8@gloomyandy are these values incorrect?; Tools M563 P0 S"volcano" D0 H1 F0 ; define tool 0 G10 P0 X0 Y0 Z0 ; set tool 0 axis offsetsBusiness, Economics, and Finance. . I would be very gratefull for any help. So no need to use M302. Re: How can I move E steppers? January 11, 2023 02:36AMFailure to extrude in RepRapFirmware is usually caused by either cold extrusion prevention (but you have sent M302 P1 to disable that), or not having the tool selected. 168. Make sure you clean out the heatblock and refit the nozzle properly, hot tightening it, etc. : Just need to find settings for Slice Engineering 300c thermistor, According to this document, you need to use the following in your M308 T100000 B4680 C6. M302 P0. What could be the causeMarlin defaults to "no cold extrusion". 1 Z0. 0C. If calibrating cold, run M302 P1 (allows cold extrusion) If calibrating hot, heat your hotend to printing temp. X moves almost free, lets say as much as you can tell with the belt installed without the steppers. 0. 4. Business, Economics, and Finance. Sending T0 initiates the heater and then faults out. g: 1. 7mm, the output contact is engaged @ about 0. Thanks for the reply. For firmware versions 1. g. M302 P1; Axis Limits M208 X-50 Y0 Z0 U0 S1 ; set axis minima M208 X210 Y220 U260 Z200 S0 ; set axis maxima ; Endstops M574 X1 S1 P"io0" ; configure switch-type (e. Click to Enlarge. ) You can feed filament at 800mm/m (web interface max speed is 240mm/m), at 100mm at a time, until the filament is near the nozzle. (You'll need to pull hard sometimes) Step 7 Printer: Anycubic Chiron, Firmware: Marlin 2. To test for this, with the power off swap the E0 connector on the Duet with another one e. Step 6. So I attached a thermistor to the board just to "fool" the board into thinking there was an active heater but then I get temperature errors. On the X and Y we are using iHSS57-36-10 closed loop. If you are using the web interface, go to the Gcode. Other possible causes are a bad stepper motor or cable. M106 P0 S0 H-1 ; set fan 0 value. 8 on Thu Feb 20 2020 13:12:07 GMT+0100 (centraleuropeisk normaltid) ; General preferences G90 ; send absolute coordinates. I'm not sure if this gets cancelled at power off. M106 P1 S1 H1 T100 ; set fan 1 value. Once installed, remove your existing tool defintion from config. Large delta printer [ miscsolutions. dmould. -> no reaction at all - even after "M302 P1" What is working: Homing. GameStop Moderna Pfizer Johnson & Johnson AstraZeneca Walgreens Best Buy Novavax SpaceX Tesla. @droftarts OK, I wish I knew which of the changes finally mattered but I don't. . 16 07:24. +Z should move the bed down. 12/28/2022, 7:23:58 PM M302 Cold extrusion is forbidden (use M302 P1 to allow it), min. g ; set bed and extruder max temperatures; --- SECTION: FANS ( ) ---M106 P0 S0 I0 F4 H-1 L0. Volume 2. Extrude a small amount to ensure that your extruder motor is on and holding. M569 P0 S1 ; Reverse the X motor M563 P0 D0 H1 ; Define tool 1 G10 P0 S0 R0 ; Set tool 1 operating and standby temperatures M563 P1 D1 H2 ; Define tool 2 (un-comment this for dual nozzle machines) G10 P1 X19 S0 R0 ; Set tool 2 operating and standby temperatures (un-comment this for dual nozzle machines) M92 E447:447 ; Set. 9mm of feed stock. GameStop Moderna Pfizer Johnson & Johnson AstraZeneca Walgreens Best Buy Novavax SpaceX Tesla. To test for this, with the power off swap the E0 connector on the Duet with another one e. 23". 0. Failure to extrude in RepRapFirmware is usually caused by either cold extrusion prevention (but you have sent M302 P1 to disable that), or not having the tool selected. Edit. ; Configuration file for Duet WiFi (firmware version 2. 042". 0C, min. 4 and an arduino mega 2560. Set the temperature (and enable) using. 3 (3. Macros also allow for naming gcodes with easier to remember names. Set nozzle and bed temperature to something below 30°C so the hotend fan wont spin up. 8Hz when using P4. g macro is;Autoload filament macro. M302 works fine in a starting script or sent via console. M98 Ppurge_bucket . I used M302 P1 and it worked fine when I was testing my new extruder stepper motor. oracledude 5 Dec 2021, 21:47. M302 P1 ; Allow Cold extrudes; Thermistors M305 P0 T100000 B3950 R2200 H30 L0 M305 P1 T100000 B3950 R2200 H30 L0 M305 P2 T100000 B3950 R2200 H30 L0. With steps/mm so low you will get nothing like enough torque out of your motor to extrude anything, unless it is a really huge motor. 1 Reply Last reply Reply Quote 0. I used to use "Pronterface" for that. @dc42 That doesn't seem to work. : till no luck with Extrusion Control jogging buttons. g. g (typically the Tools section) but write down the configured heater, fan, and extruder numbers mapped to. What am I doing wrong? Thanks in advanceM302: Allow cold extrudes Examples M302 M302 P1 This tells the printer to allow movement of the extruder motor, when the hotend is not at printing temperature. M569 P1 S1 D3 V0 ; Drive 1 goes forwards, CoreXY_2, stealth chop, disable spread cycle M569 P2 S1 D3 V0 ; Drive 2 goes forwards, Z Motor, stealth chop, disable spread cycle. How can I make reprap firmware print without any heater or temperature sensors? Does it have a fake heater that I can make always return 200c or something to make the firmware extrude with a cold extruder, or even wi. yello3d. The belts are not over tight. . M302 P0. This document describes the commands that Klipper supports. Now all the other axis are moving as supposed but the extruder ones are not. 0. Only users with topic management privileges can see it. Re: Extrude without a Hotend May 04, 2017 11:25PM. Ok I will try the bugfix branch with the config files you provided! G10 P1 X0 Y0 Z0 ; Set tool 1 axis offsets G10 P1 R0 S0 ; Set initial tool 1 active and standby temperatures to 0C M302 S120 R110 ; Allow extrusion starting from 120°C and retractions already from 110°C G10 P1 X0 Y0 Z0 ; Set tool 1 axis offsets G10 P1 R0 S0 ; Set initial tool 1 active and standby temperatures to 0C M302 S120 R110 ; Allow extrusion starting from 120°C and retractions already from 110°C I need to print some PCL filament, which melts optimally at 100 C°. Looking for a way that is super native, standalone and low end way to get it to do that without using high level programming architecture, such as not using software that is running on python or what not. M116 P0 ; wait for heating up. 0. Unmount the SD card and insert it into the Duet 2 Maestro board and power on. To print at this lower temperature, g-code command M302 P1 was used to disable the printer’s cold extrusion checking. I can get the x,y,and z motors moving in pronterface, but the extruder…@jfavre said in Extruder motor not working. G10 P1 X0 Y0 Z0 ; Set tool 1 axis offsets G10 P1 R0 S0 ; Set initial tool 1 active and standby temperatures to 0C M302 S120 R110 ; Allow extrusion starting from 120°C and retractions already from 110°C The retract and extrude control in extrusion control panel can't be active. but if i want -z to go down shouldnt 0 be at the bottom? how would i swap that around, change the motor direction like you suggested in your last post?I did try a cold extrude M302 P1. As well as selecting the tool with e. Only users with topic management privileges can see it. 6, no change. When tfreeN is called, filament is retracted above the y-splitter. My config file is in experimental stages, but the Cartesian axis worked. @jens55 you are right dude I had missing to remplace one "S" argument by "H" in homez. Only users with topic management privileges can see it. How would I know to send a T0 and then M302 P1 to test the extruder? Quote dc42 Make sure you have a tool selected (e. Let me explain better: I need to set the T0 value to 170/25 degrees as dummy to run the right Titan to verify the right amount of filament that extr. Check if extruder motor making any noise. Last edit at 01/11/2023 01:58AM by Dust. Macros also allow for naming gcodes with easier to remember names. Send M302 P1 to allow Cold extrusion Send M600 T1 to initiate Filament swap Follow the Instructions on the Screen. 3 Then I think you should config the BLTouch differently: Have you read this bit, "Software setup (. . Ralms @fcwilt 8 Aug 2020, 08:57. droftarts administrators @flyscha last edited by . I'm attempting to drive I was successful in driving a Maxon DC motor with encoder (pulled from a Stratasys Dimension 1200es BST) with a Duet 2 Wifi via a Geckodrive G320x. If calibrating cold: Bowden: Disconnect the bowden tube from your extruder. G-Codes¶. Without inserting the wire I tried to make a print and the extruder works. what gcode do i need to send… Premium ExploreTo install this plugin, open DWC, go to Settings -> Plugins -> External Plugins and click on "Install Plugin". Heater 1 fault: temperature rising too slowly: expected 2. Last edit at 01/11/2023 01:58AM by Dust. Heating Bed manually by G-Code. These are commands that one may enter into the OctoPrint terminal tab. I just wondered if there was a way of "embedding" it in the config files so that it runs by default. droftarts administrators @flyscha last edited by . Fan1 configured in thermostatic mode by default. Wood filament wont extrude / print below 200deg. Trying to figure out why I can't run my extruder. Then reduce the distance, and stop just before the filament disappears into the hot end. . Saying G0/G1 insufficient homing What could be the reasonThis topic has been deleted. Example output if disabled: echo:Cold extrudes are disabled (min temp 170C) Example output if enabled: To temporarily disable the MIN_TEMP, you need to run the G-code M302 P1 or M302 S0 - M302 on its own does nothing. it has a bowden setup and i have the bowden tube off. microswitch) endstop. M302. g at here G91 ; relative positioning G1 Z5 F6000 S2 <--(problem is here, remplace S2 by H2) ; lift Z relative to current position G90. 0. I made a clay extruder for my printer. 00 and cannot get the stepper motors of the extruders to work. g: T0 ; select tool 0. Brought to you with lack of and lots of .